Murphy Automatic Engine Controller AS3000 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačové příslušenství Murphy Automatic Engine Controller AS3000. Murphy Automatic Engine Controller AS3000 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 2
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
AS3000-02127B page 1 of 2
AS3000-02127B
Revised 05-03
Catalog Section 75
(00-02-0525)
Automatic Engine Controller
FWMurphy
AS3000 Model
Auto crank disconnect
Multi-attempt starting
Fault warning and shutdown
Reduced panel wiring
Simple set set-up
Description
The AS3000 provides automatic start up, fault mon-
itoring and shutdown control for engine driven
applications. The unique two-module design, with a
single interconnecting lead, gives reduced panel
wiring and installation. This simple, compact unit is
ideally suited to small engine and generator panels.
Key features
Multi-attempt cranking with auto crank disconnect
Automatic or manual modes, selected by front
facia pushbuttons. Control inputs for optional
security keyswitch.
User inteface module: front of panel mounted,
92mm square DIN cut-out. Environmental
sealing to IP65
Panel interface module: DIN rail mounted
PCB tray.
Fault shutdown and indication system. Low oil
pressure, high coolant temperature and auxil-
iary inputs are fitted to both modules, allowing
use with engine mounted fault switches or
panel mounted SWICHGAGE
®
units.
Speed sensing (auto crank disconnect and over-
speed shutdown) is via magnetic pickup, gen-
erator AC or remote contact. Speed calibration
is automatic and adjustment free.
Mains charger/charge alternator fail warning LED.
Easy setup of operating options using circuit
board links.
Generator AC Hz meter output, 0 – 5V.
Product Specification
Power supply
Continuous voltage range: 8 – 35 VDC
Brown out voltage: < 5 VDC for 2 secs
(recovery to 8V)
Blackout voltage: 0V for 50mS (from 10V,
recovery to 5V)
Overvoltage withstand: 50 VDC for 5 sec-
onds (to SAEJ1810 load dump immunity)
Reverse voltage withstand:
100 VDC continuous.
Current consumption (standby): 50mA.
Current consumption (max): 500mA (plus
output loads).
DC Inputs
Oil pressure, coolant temp, auxiliary and
charger faults: Closed to negative DC
(±3V) on fault.
Remote start positive: Open from positive
DC to start.
Remote start negative: Close to negative DC
(±3V) to start.
Lamp test: Close to negative DC (±3V)
to activate.
DC input protection: ±50 VDC maximum.
AC Inputs
Magnetic pickup: 3 – 60 VAC, 50Hz – 10 kHz.
Generator AC: 600 VAC maximum (L-L or
L-N), 50/60 Hz.
Outputs
Fuel: positive DC (transistor), 5A max.
Crank, preheat: positive DC (transistor),
2A max.
Common alarm, fault lockout: negative DC
(
transistor), 300mA max.
Generator Hz. Meter: 0-1mA (@ 45 - 65 Hz).
Physical
Dimensions: see “System Overview” on page 2.
Operating temperature: 14 to 149°F (-10 to
+65°C).
Relative humidity: 95% @ 140°F (60 °C).
Environmental protection: AS3000 front:
IP65, NEMA4.
Back of User Interface and Panel interface
require weather-proof enclosures for outdoor use.
Vibration: ISO 88528 pt.9, & 3 axis 3g.
Weight:
AS3000 User Interface: approx. 9 oz. (250g).
AS300 Panel Interface: approx. 6 oz. (160g).
Shipping Weight: 1 lb. 4 oz. (554 g.).
Shipping Dimensions: 7-3/8 x 5 x 3-1/8 inch.
(187 x 127 x 79 mm.).
Zobrazit stránku 0
1 2

Shrnutí obsahu

Strany 1 - Automatic Engine Controller

AS3000-02127B page 1 of 2AS3000-02127BRevised 05-03Catalog Section 75(00-02-0525)Automatic Engine ControllerFWMurphyAS3000 Model Auto crank disconnect

Strany 2 - How to order

AS3000-02127B page 2 of 2How to orderStock no. Unit typeComplete systems:41.70.0093 AS3000 system, white faceplate41.70.0100 AS3000 system, black f

Komentáře k této Příručce

Žádné komentáře